Latest Adqueo update: Fix · CMMS: PM schedule drift on DST boundariesSee what's new →
Adqueoby Tecapa

Energy· Early access

Consumption, baseline, and savings have to agree.

Adqueo Energía is energy-management software and consultancy for commerce, industry, and public institutions: meters, baselines, opportunities, and verification in one record. Electricity, steam, water, air, and cooling are never added together. A result is not verified until there is a method, a reviewer, and evidence.

Planta Pilar · electricity · August 2026

412.800 kWh

6,2 % below baseline

61014181581216202428

ActualBaselineDay 8 estimated · rest measured

Sample view

THE VISION BEHIND THE PRODUCT

Energy is managed when the reading and the decision live together.

I have audited energy management systems and seen reports that do not reconcile to the meter. I want Adqueo Energía to hold consultancy to the same standard: one magnitude, one baseline, and a result someone can sign.

  • Keep electricity, steam, water, air, and cooling apart so a cost is not invented by adding different units.

  • Require a baseline, a method, and a reviewer before a saving is called verified.

  • Keep the improvement file — investment, assumption, evidence — in the same place as the reading.

Daniel JiménezFounder of Adqueo

Verifiable savings in plants with an EnMS — not Adqueo results.

  • 4%

    first-year energy-performance gain at SEP 50001 plants (LBNL)

  • ~12%

    cumulative at three years if the EnMS is kept alive

  • 20–50%

    of compressed-air use, recoverable in leaks and pressure (DOE)

  • 10–15%

    typical on steam: traps, condensate, insulation

Technician holding a three-phase power quality analyzer, test leads on an outdoor capacitor bank.

Measurement

Every reading says where it comes from.

Metered, estimated, or missing: each meter states it, along with the instrument behind it — a power analyzer, a billing meter, or a pulse. Real data never gets mistaken for a guess.

Infrared thermogram of an industrial electric motor: housing and fins running hot, drive end cooler.

Loss

Losses don't always show up on the bill.

A hot motor or a steam leak is found on the floor and with thermography, not in the incoming total. Finding them is the first step; the saving stays estimated until there is a method, a reviewer, and evidence.

Applicability

One method, three realities.

The discipline does not change with the sector: measure, baseline, reviewer, evidence. The utilities and drivers change.

  • Shopping-center parking deck at golden hour, empty lanes and warm light.

    Commerce

    Retail, offices, shopping centers

    Contracted demand, schedule, and HVAC drive the bill. The saving is proven the same way.

    • Demand and power factor
    • Schedule and occupancy
    • HVAC and lighting
  • CNC machining bay with overhead crane and skylights on a factory floor.

    Industry

    Food, manufacturing, cold chain

    Production is the variable. Electricity, steam, water, air, and cooling — each in its unit, never added together.

    • Production as a baseline driver
    • Utility balances per unit
    • Compressed air, steam, cooling
  • Cream-colored municipal government building with an arcaded facade and flagpoles at golden hour, an empty plaza in front.

    Government / public institutions

    Municipalities, hospitals, schools, public lighting

    Public budgets demand accountability. Every colón is defended with an auditable record, not a slide.

    • Auditable, transparent verification
    • Budget accountability
    • Multi-site public portfolios

The product

This is not a screenshot. It is the software.

Switch tabs, filter, open a row. That screen is the product.

Cost, baseline, verified savings, and the next decision — for the client and plant in scope.

Adqueo EnergíaExecutive summarySample view
Alimentos del Sur/Planta Pilaragosto 2026
Centro de control

Resumen ejecutivo

Una mirada clara a tu desempeño energético.

Ver informesCargar datos
Indicadores96,1 % de datos medidos
Costo de utilidades
US$ 138.400
Acumulado del período
Desempeño eléctrico
6,2 %
MejoraConsumo frente a referencia
Ahorro verificado
—
En verificaciónPendiente de revisión técnica
Acciones pendientes
09
En curso3 requieren atención
Consumo y referenciaEvolución diaria · medición y seguimiento
412.800kWh
Consumo realReferencia
612181581216202428
Referencia registrada · kWhAbrir análisis
Distribución del costoParticipación por utilidad
US$ 138.400USD · período seleccionado

Los costos térmicos corresponden a su asignación al vapor. No se suman dos veces los combustibles.

Oportunidades prioritarias4 mejoras en tu cartera
Ver todas
OportunidadAhorro estimado / añoEstado
Aislar válvulas del colectorPlanta PilarUS$ 3.400Detectada
Variador en bomba de alimentaciónPlanta PilarUS$ 4.900En evaluación
Reparar fugas de vaporPlanta PilarUS$ 8.700Acuerdo de medición
Control de demanda en envasadoPlanta PilarUS$ 8.100En evaluación
Requiere tu atenciónAlertas abiertas
03
Ir al centro de alertas
The ISO map holds owners and evidence. It is not a certificate. A calculated saving is not labeled verified until technical review.

Capabilities

You already saw the UI. This is the inventory of records that have to agree.

  • Meters and data quality

    Main meters, submeters, estimated days, and a correction that keeps the original reading.

  • Utility balances

    Electricity, steam, water, air, cooling — each in its unit. They are never added together.

  • Baselines

    A linear model against production, with R², exclusions, and a technical review before it is approved.

  • Opportunity board

    Investment, estimated annual saving, and simple payback — still labeled estimated until verified.

  • M&V agreements

    Method, boundary, and reviewer before execution. Calculated is not verified.

  • Energy management map

    Owners and evidence for the EnMS. It is not a certificate.

Sensors and instruments

The tree is fed by a named instrument. There is no generic SCADA connector: API, CSV, or register, depending on the plant.

  • Power analyzer

    Active energy, demand, THD. Modbus or a campaign download — the instrument that closes the electrical single-line.

  • Pulse SO / billing meter

    The incoming total. Without it the tree does not close, however many submeters you add.

  • 4–20 mA, vortex, orifice

    Steam, water, air: each in its unit. A milliamp is never added to a kWh.

  • Thermography

    A campaign, not a continuous meter. It finds the hot spot; it does not invent a verified saving.

Public good

The methodology is open.

The software is the product; the method to prove a saving is public and reproducible. Anyone can audit how a consumption became a saving.

  1. 01

    Measure

    Each point marks its instrument: metered, estimated, or missing. Without one, the number doesn't hold up.

  2. 02

    Baseline

    A model against production, with R² and documented exclusions. The reference can be reproduced.

  3. 03

    Reviewer

    Method, boundary, and adjustments agreed before execution. A second pair of eyes signs.

  4. 04

    Evidence

    The calculation keeps its data and its review. Calculated is not verified until this step.

A saving that cannot be reproduced is not a saving. That is why the method is not locked away: it is documented, auditable, and outlives the tool and the vendor.

Pricing for Adqueo Energía

Early access. When it opens, Professional is US$299 / month and includes everything. Field work and IoT are quoted separately.

Professional is US$299 / month and includes everything. Thermography, field analysis, and IoT are quoted separately.

Professional includes everything in the product. Starter is a smaller scope. Enterprise is a contract. Field campaigns and IoT meter integration are billed separately.

Recommended

Professional

US$299/ mo

Includes everything.

Contact us
CapabilityStarterProfessionalEnterprise
Meters and qualityIncludedIncludedIncluded
Utility balancesIncludedIncludedIncluded
BaselinesSimpleIncludedIncluded
Board and M&VNot includedIncludedIncluded
Published reportsNot includedIncludedIncluded
API / SSO / Multi-sitioNot includedIncludedIncluded

Questions

See the software. Or tell us the loop that does not fit.

The suite lives here. If the loop does not fit, let’s talk about custom software.

If the process does not fit this product — custom software →